Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Anal Biochem ; 641: 114565, 2022 03 15.
Artículo en Inglés | MEDLINE | ID: covidwho-1632512

RESUMEN

Polymerase chain reaction (PCR) is the most widely used method for nucleic acids amplification. To date, a huge number of versatile PCR techniques have been developed. One of the relevant goals is to shorten PCR duration, which can be achieved in several ways. Here, we report on the results regarding nucleic acids amplification by convective PCR (cPCR) in standard 0.2 ml polypropylene microtubes. The following conditions were found to be optimal for such amplification: 1) 70 µl reaction volume, 2) the supply of external temperature 145°Ð¡ for the denaturation zone and 0°Ð¡ for the annealing zone, 3) ∼30° inclination of the microtube main axis, 4) the use of nearby primers, and 5) duration of the reaction 15-20 min. At these conditions, the amplification products are accumulated in an amount sufficient to be registered by gel electrophoresis, and high sensitivity of the reaction comparable to that of conventional PCR is achieved. cPCR provided the reliable detection of SARS-CoV-2 coronavirus RNA isolated from nasopharyngeal swabs of COVID-19 patients.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/instrumentación , COVID-19/diagnóstico , Reacción en Cadena de la Polimerasa/instrumentación , SARS-CoV-2/aislamiento & purificación , COVID-19/virología , Prueba de Ácido Nucleico para COVID-19/economía , Prueba de Ácido Nucleico para COVID-19/métodos , Convección , Humanos , Reacción en Cadena de la Polimerasa/economía , Reacción en Cadena de la Polimerasa/métodos , ARN Viral/análisis , ARN Viral/genética , SARS-CoV-2/genética , Temperatura , Factores de Tiempo
2.
Mol Biotechnol ; 64(4): 339-354, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: covidwho-1469770

RESUMEN

The outbreak of COVID-19 pandemic and its consequences have inflicted a substantial damage on the world. In this study, it was attempted to review the recent coronaviruses appeared among the human being and their epidemic/pandemic spread throughout the world. Currently, there is an inevitable need for the establishment of a quick and easily available biosensor for tracing COVID-19 in all countries. It has been known that the incubation time of COVID-19 lasts about 14 days and 25% of the infected individuals are asymptomatic. To improve the ability to determine SARS-CoV-2 precisely and reduce the risk of eliciting false-negative results produced by mutating nature of coronaviruses, many researchers have established a real-time reverse transcriptase-polymerase chain reaction (RT-PCR) assay using mismatch-tolerant molecular beacons as multiplex real-time RT-PCR to distinguish between pathogenic and non-pathogenic strains of coronaviruses. The possible mechanisms and pathways for the detection of coronaviruses by biosensors have been reviewed in this study.


Asunto(s)
Prueba de COVID-19/métodos , Técnicas Biosensibles/métodos , Prueba de COVID-19/instrumentación , Sistemas CRISPR-Cas , Técnicas Electroquímicas , Ensayo de Inmunoadsorción Enzimática , Técnica del Anticuerpo Fluorescente/métodos , Humanos , Técnicas de Diagnóstico Molecular/instrumentación , Técnicas de Diagnóstico Molecular/métodos , Pruebas de Neutralización , Técnicas de Amplificación de Ácido Nucleico/instrumentación , Técnicas de Amplificación de Ácido Nucleico/métodos , Reacción en Cadena de la Polimerasa/instrumentación , Reacción en Cadena de la Polimerasa/métodos , SARS-CoV-2/patogenicidad , Resonancia por Plasmón de Superficie
3.
Biosensors (Basel) ; 11(5)2021 May 01.
Artículo en Inglés | MEDLINE | ID: covidwho-1223947

RESUMEN

Molecular diagnostics has been the front runner in the world's response to the COVID-19 pandemic. Particularly, reverse transcriptase-polymerase chain reaction (RT-PCR) and the quantitative variant (qRT-PCR) have been the gold standard for COVID-19 diagnosis. However, faster antigen tests and other point-of-care (POC) devices have also played a significant role in containing the spread of SARS-CoV-2 by facilitating mass screening and delivering results in less time. Thus, despite the higher sensitivity and specificity of the RT-PCR assays, the impact of POC tests cannot be ignored. As a consequence, there has been an increased interest in the development of miniaturized, high-throughput, and automated PCR systems, many of which can be used at point-of-care. This review summarizes the recent advances in the development of miniaturized PCR systems with an emphasis on COVID-19 detection. The distinct features of digital PCR and electrochemical PCR are detailed along with the challenges. The potential of CRISPR/Cas technology for POC diagnostics is also highlighted. Commercial RT-PCR POC systems approved by various agencies for COVID-19 detection are discussed.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/instrumentación , COVID-19/diagnóstico , Pruebas en el Punto de Atención , Reacción en Cadena de la Polimerasa/instrumentación , SARS-CoV-2/aislamiento & purificación , Animales , Prueba de Ácido Nucleico para COVID-19/métodos , Sistemas CRISPR-Cas , Diseño de Equipo , Humanos , Reacción en Cadena de la Polimerasa/métodos , SARS-CoV-2/genética
4.
Biotechniques ; 69(4): 317-325, 2020 10.
Artículo en Inglés | MEDLINE | ID: covidwho-1067502

RESUMEN

PCR has become one of the most valuable techniques currently used in bioscience, diagnostics and forensic science. Here we review the history of PCR development and the technologies that have evolved from the original PCR method. Currently, there are two main areas of PCR utilization in bioscience: high-throughput PCR systems and microfluidics-based PCR devices for point-of-care (POC) applications. We also discuss the commercialization of these techniques and conclude with a look into their modifications and use in innovative areas of biomedicine. For example, real-time reverse transcription PCR is the gold standard for SARS-CoV-2 diagnoses. It could also be used for POC applications, being a key component of the sample-to-answer system.


Asunto(s)
Reacción en Cadena de la Polimerasa/métodos , Animales , Betacoronavirus/genética , Betacoronavirus/aislamiento & purificación , COVID-19 , Prueba de COVID-19 , Técnicas de Laboratorio Clínico/instrumentación , Técnicas de Laboratorio Clínico/métodos , Infecciones por Coronavirus/diagnóstico , Infecciones por Coronavirus/virología , Diseño de Equipo , Humanos , Técnicas Analíticas Microfluídicas/instrumentación , Técnicas Analíticas Microfluídicas/métodos , Pandemias , Neumonía Viral/diagnóstico , Neumonía Viral/virología , Sistemas de Atención de Punto , Reacción en Cadena de la Polimerasa/instrumentación , SARS-CoV-2
5.
Lab Chip ; 20(19): 3560-3568, 2020 10 07.
Artículo en Inglés | MEDLINE | ID: covidwho-798864

RESUMEN

A miniaturized polymerase chain reaction (PCR) system is not only important for medical applications in remote areas of developing countries, but also important for testing at ports of entry during global epidemics, such as the current outbreak of the coronavirus. Although there is a large number of PCR sensor systems available for this purpose, there is still a lack of portable digital PCR (dPCR) heating systems. Here, we first demonstrated a portable plasmonic heating-based dPCR system. The device has total dimensions of 9.7 × 5.6 × 4.1 cm and a total power consumption of 4.5 W, allowing for up to 25 dPCR experiments to be conducted on a single charge of a 20 000 mAh external battery. The dPCR system has a maximum heating rate of 10.7 °C s-1 and maximum cooling rate of 8 °C s-1. Target DNA concentrations in the range from 101 ± 1.4 copies per µL to 260 000 ± 20 000 copies per µL could be detected using a poly(dimethylsiloxane) (PDMS) microwell membrane with 22 080 well arrays (20 µm diameter). Furthermore, the heating system was demonstrated using a mass producible poly(methyl methacrylate) PMMA microwell array with 8100 microwell arrays (80 µm diameter). The PMMA microwell array could detect a concentration from 12 ± 0.7 copies per µL to 25 889 ± 737 copies per µL.


Asunto(s)
Reacción en Cadena de la Polimerasa/instrumentación , Algoritmos , Técnicas Biosensibles , ADN/química , Suministros de Energía Eléctrica , Humanos , Membranas Artificiales , Miniaturización , Polimetil Metacrilato
6.
PLoS One ; 15(8): e0237418, 2020.
Artículo en Inglés | MEDLINE | ID: covidwho-713417

RESUMEN

The coronavirus disease 2019 (COVID-19) pandemic has crudely demonstrated the need for massive and rapid diagnostics. By the first week of July, more than 10,000,000 positive cases of COVID-19 have been reported worldwide, although this number could be greatly underestimated. In the case of an epidemic emergency, the first line of response should be based on commercially available and validated resources. Here, we demonstrate the use of the miniPCR, a commercial compact and portable PCR device recently available on the market, in combination with a commercial well-plate reader as a diagnostic system for detecting genetic material of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the causal agent of COVID-19. We used the miniPCR to detect and amplify SARS-CoV-2 DNA sequences using the sets of initiators recommended by the World Health Organization (WHO) for targeting three different regions that encode for the N protein. Prior to amplification, samples were combined with a DNA intercalating reagent (i.e., EvaGreen Dye). Sample fluorescence after amplification was then read using a commercial 96-well plate reader. This straightforward method allows the detection and amplification of SARS-CoV-2 nucleic acids in the range of ~625 to 2×105 DNA copies. The accuracy and simplicity of this diagnostics strategy may provide a cost-efficient and reliable alternative for COVID-19 pandemic testing, particularly in underdeveloped regions where RT-QPCR instrument availability may be limited. The portability, ease of use, and reproducibility of the miniPCR makes it a reliable alternative for deployment in point-of-care SARS-CoV-2 detection efforts during pandemics.


Asunto(s)
Betacoronavirus/genética , Infecciones por Coronavirus/diagnóstico , Neumonía Viral/diagnóstico , Sistemas de Atención de Punto , Reacción en Cadena de la Polimerasa/instrumentación , Reacción en Cadena de la Polimerasa/métodos , Secuencia de Bases , Betacoronavirus/química , COVID-19 , Infecciones por Coronavirus/virología , Proteínas de la Nucleocápside de Coronavirus , ADN Viral/genética , Exactitud de los Datos , Humanos , Proteínas de la Nucleocápside/genética , Pandemias , Fosfoproteínas , Neumonía Viral/virología , Reacción en Cadena de la Polimerasa/economía , Reproducibilidad de los Resultados , SARS-CoV-2 , Sensibilidad y Especificidad
8.
Biosens Bioelectron ; 165: 112349, 2020 Oct 01.
Artículo en Inglés | MEDLINE | ID: covidwho-459213

RESUMEN

Timely detection and diagnosis are urgently needed to guide epidemiological measures, infection control, antiviral treatment, and vaccine research. In this review, biomarkers/indicators for diagnosis of coronavirus disease 2019 (COVID-19) or detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in the environment are summarized and discussed. It is concluded that the detection methods targeting antibodies are not suitable for screening of early and asymptomatic cases since most patients had an antibody response at about 10 days after onset of symptoms. However, antibody detection methods can be combined with quantitative real-time reverse transcriptase-polymerase chain reaction (RT-qPCR) to significantly improve the sensitivity and specificity of diagnosis, and boost vaccine research. Fast, sensitive and accurate detection methods targeting antigens need to be developed urgently. Various specimens for diagnosis or detection are compared and analyzed. Among them, deep throat saliva and induced sputum are desired for RT-qPCR test or other early detection technologies. Chest computerized tomography (CT) scan, RT-qPCR, lateral flow immunochromatographic strip (LFICS) for diagnosis of COVID-19 are summarized and compared. Specially, potential electrochemical (EC) biosensor, surface enhanced Raman scattering (SERS)-based biosensor, field-effect transistor (FET)-based biosensor, surface plasmon resonance (SPR)-based biosensor and artificial intelligence (AI) assisted diagnosis of COVID-19 are emphasized. Finally, some commercialized portable detection device, current challenges and future directions are discussed.


Asunto(s)
Betacoronavirus/aislamiento & purificación , Técnicas Biosensibles/instrumentación , Infecciones por Coronavirus/diagnóstico , Neumonía Viral/diagnóstico , Animales , Anticuerpos Antivirales/análisis , Antígenos Virales/análisis , Técnicas Biosensibles/métodos , COVID-19 , Cromatografía de Afinidad/instrumentación , Cromatografía de Afinidad/métodos , Monitoreo del Ambiente/instrumentación , Monitoreo del Ambiente/métodos , Diseño de Equipo , Humanos , Pandemias , Reacción en Cadena de la Polimerasa/instrumentación , Reacción en Cadena de la Polimerasa/métodos , ARN Viral/análisis , Tiras Reactivas/análisis , SARS-CoV-2 , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA